Check our new range of heat guns - Now 10% Off!

HSE Safety Box (RCCB) 230V & 32amp 25 Metre Armoured Extension Cable for Leister Welding Machines - Purchase or Hire

Product image
SKU: SAFETY-BOX-RCCB&HTP-25MTR-ARMOURED-CABLE

Waterproof Armoured extension lead for 230V applications 25mtrs long and Residual Current Circuit Breaker Safety Box for use with our Leister Welding Machines. Save when bought together as a package or consider a short-term hire!

Hire Me Click Here

This machine is also available for hire with an option to purchase the machine after the hire period. It can be hired with a small deposit and weekly payments. Minimum term is 2 weeks. Please contact our sales team for more details.

Configure Product
Our Price (Excl VAT)
£127.99
Inc VAT
£153.59

Hire Me Form

 

NEW - HSE (RCCB) Residual Current Circuit Breaker Unit

Hire Me

Genuine accessory approved by Leister

Utilised for Leister Welding Machines and RCCB Safety Boxes. Designed to provide safety against electrocution by detecting current leaks. In the presence of electronic malfunction, the RCCB will trip and prevent further current from entering the system, meaning a reduced risk of injury, electronic failure and fires. Particularly useful for larger electronic devices such as our welding machines.

The RCCB unit is fitted with a lockable selector switch marked for “mains” or “generator”. The latter position provides the reference connections required for correct operation of the RCCB when a generator is used.

The Residual Current Circuit Breaker (RCCB) Unit should be plugged in either to the fixed supply or to the generator via its 2m lead. This unit should be mounted securely above ground level if possible. If not then it should be stood on the floor/ground in a position where it is unlikely to be damaged and firmly held down with sandbags or weights so that it cannot be knocked over.

Safety Information:

The RCCB should be tested each day before work commences.

Connect the equipment to the power supply as above with the isolator in the OFF position and the RCCB ON/OFF switch (behind clear plastic panel) to OFF. Switch on the isolator, then the RCCB and press the test button. The RCCB should trip out. If it doesn’t, check that there is power to the RCCB. If there is, the RCCB unit is faulty. It should not be used but returned to Hilltop Products immediately for inspection.

ANY QUERIES ABOUT THE CORRECT OR SAFE FUNCTIONING OF THE EQUIPMENT SHOULD BE REFERRED TO THE SUPPLIER.

 

NEW - 4Z 25mtr 230V Waterproof Armoured Extension Lead

Utilised for Leister Welding Machines and RCCB Safety Boxes. 3mm x 4mm square - 12mm Diameter

Safety Information:

Leads must never coiled up when in use. When couplers are in use, the 2 halves should be secured by the locking ring to prevent seperation.

 
Quick Search Code 104847
 

NEW - HSE (RCCB) Residual Current Circuit Breaker Unit

Hire Me

Genuine accessory approved by Leister

Utilised for Leister Welding Machines and RCCB Safety Boxes. Designed to provide safety against electrocution by detecting current leaks. In the presence of electronic malfunction, the RCCB will trip and prevent further current from entering the system, meaning a reduced risk of injury, electronic failure and fires. Particularly useful for larger electronic devices such as our welding machines.

The RCCB unit is fitted with a lockable selector switch marked for “mains” or “generator”. The latter position provides the reference connections required for correct operation of the RCCB when a generator is used.

The Residual Current Circuit Breaker (RCCB) Unit should be plugged in either to the fixed supply or to the generator via its 2m lead. This unit should be mounted securely above ground level if possible. If not then it should be stood on the floor/ground in a position where it is unlikely to be damaged and firmly held down with sandbags or weights so that it cannot be knocked over.

Safety Information:

The RCCB should be tested each day before work commences.

Connect the equipment to the power supply as above with the isolator in the OFF position and the RCCB ON/OFF switch (behind clear plastic panel) to OFF. Switch on the isolator, then the RCCB and press the test button. The RCCB should trip out. If it doesn’t, check that there is power to the RCCB. If there is, the RCCB unit is faulty. It should not be used but returned to Hilltop Products immediately for inspection.

ANY QUERIES ABOUT THE CORRECT OR SAFE FUNCTIONING OF THE EQUIPMENT SHOULD BE REFERRED TO THE SUPPLIER.

 

NEW - 4Z 25mtr 230V Waterproof Armoured Extension Lead

Utilised for Leister Welding Machines and RCCB Safety Boxes. 3mm x 4mm square - 12mm Diameter

Safety Information:

Leads must never coiled up when in use. When couplers are in use, the 2 halves should be secured by the locking ring to prevent seperation.

 

You might also like

230V / 16amp 25 Metre Waterproof Armoured Extension Cable/Hook up Lead for Leister Welding Machines

Our Price:

£119.99 £99.99

230V / 32amp 25 Metre Waterproof Armoured Extension Cable/Hook up Lead for Leister Welding Machines

Our Price:

£179.99 £149.99

HSE Safety Kit Box 230V for Leister Welding Machines (RCCB)

Our Price:

£965.99 £804.99